Tabela 0472 - TQ Conjunction ID

Item#DescriçãoComentários
S Synchronous Do the next specification after this one (unless otherwise constrained by the
following fields:
TQ1-7-start date/time and TQ1-8-end date/time). An "S"
specification implies that the second timing sequence follows the first, e.g.,
when a service request is written to measure blood pressure Q15 minutes for
the 1st hour, then every 2 hours for the next day.
A Asynchronous Do the next specification in parallel with this one (unless otherwise constrained
by the following fields:
TQ1-7-start date/time and TQ1-8-end date/time). The
conjunction of "A" specifies two parallel instructions, as are sometimes used in
medication, e.g., prednisone given at 1 tab on Monday, Wednesday, Friday,
and at 1/2 tab on Tuesday, Thursday, Saturday, Sunday.
C Actuation Time It will be followed by a completion time for the service. This code allows one to
distinguish between the time and priority at which a service should be actuated
(e.g., blood should be drawn) and the time and priority at which a service should
be completed (e.g., results should be reported).